E300 ELEVATOR AC DRIVES | 200 – 240 Vac | 06200330A10, 66 A | 33 A

For enquiry, please scroll down to description list and click on the link.

(No reviews yet) Write a Review
1 Year Warranty

To Make Enquiries

Via Email: Please click on this link HERE

Via WhatsApp: Please click on this link → HERE


Descriptions

Dedicated elevator drives that are easy to set-up and optimize while providing class-leading ride comfort.

Control Techniques is a leading supplier of variable speed drive technology to the elevator industry , with over 3 million elevators in operation with our control equipment worldwide.

Backed by our global network of Automation Centers we provide local expertise and support, along with quick delivery of robust and dependable products.

 

Related Documents

E300 Installation Guide Issue 1.book

NID12048 - NIDEC Elevator Brochure Stage 05.indd

 

Features

Rapid set-up and adjustment

  • Simple and intuitive parameter adjustment via a bright back-lit LCD keypad
  • Set-up in familiar elevator language and units
  • Easy to use menu structure for quick and simple access to key adjustments
  • Top level menu; all your frequently needed functions in one location
  • Stationary autotune provides encoder phasing test without the need to de-rope the system or to open the motor brakes

Optimum ride comfort

  • Direct-to-floor positioning
  • Peak curve operation
  • High resolution multi-step S-ramp for start, run, slowdown and stopping
  • Ultra-fast current loop for vibration free motor control
  • Advanced brake control management, no rollback on starting without the need of load sensor

Silent operation

  • EN81-20 / EN81-50 TÜV certified STO enable input removes the need for both output motor contactors
  • High switching frequencies selectable up to 16 kHz
  • Variable speed cooling fan

Energy efficient

  • Standby sleep/wake mode, powers down unused circuitry during prolonged periods of standby
  • Easy connection to a range of regenerative modules

Flexible integration

  • Modbus RTU communications
  • Parallel I/O interface
  • +/- 10V analog reference control
  • Direct RS485 comms control
  • DCP3 and DCP4 communication support with optional System Integration module
  • CAN open communication support with optional System Integration module
  • Tile mount for low profile shaft mounting
  • 24 Vdc backup
  • Simple UPS connection with load direction signal
  • Dynamic braking transistor fitted to all drives as standard

Robust

  • Active thermal management for tripless operation under extreme conditions
  • Advanced power circuit design using latest IGBT technology
  • Conformal coating for use in harsh environments
  • Phase loss detection on both input and output

Enhanced elevator data logger

  • User configurable, for example speed reference, speed feedback, current and I/O sequence can all be recorded for every car journey
  • Can be stored in the event of system fault
  • Available for offline viewing to aid system diagnostics

 

Specifications

Key data

  • Dedicated Elevator drive

Standard features

Onboard comms:

  • RS485 communications port MODBUS RTU with integrated command word and built in watchdog

Safety:

  • 1 x Sage Torque Off (STO) terminal
  • SIL3 / PLe compliant

Keypad:

  • Dedicated elevator keypad supplied as standard, providing:
    • Intuitive elevator application menu structure
    • Easy click-in keypad connection
    • Easy-to-use menu and parameter structure
    • Local and remote mounting
    • Real-time clock

Option slots:

  • 3

Parameter cloning via:

  • PC tools
  • Smartcard
  • SD card

 

200 – 240 Vac, 50-60 Hz ± 10% Drive Ratings

PART NUMBER CURRENT (A)
Peak Current Nominal Current
03200106A10 21.2 A 10.6 A
04200137A10 27.4 A 13.7 A
04200185A10 37 A 18.5 A
05200250A10 50 A 25 A
06200330A10 66 A 33 A
06200440A10 88 A 44 A
07200610A10 122 A 61 A
07200750A10 150 A 75 A
07200830A10 166 A 83 A
08201160A10 232 A 116 A
08201320A10 264 A 132 A
09201760A10 352 A 176 A
09202190A10 438 A 219 A
10202830A 566 A 283 A
10203000A 600A 300 A

For all above
Switching frequency 8 kHz(selectable 3 to 16 kHz @ 50 % ED)
Braking transistor built in as standard

380 – 480 Vac, 50-60 Hz ± 10% Drive Ratings

PART NUMBER CURRENT (A)
Peak Current Nominal Current
03400062A10 11 A 6.2 A
03400078A10 14 A 7.8 A
03400100A10 18 A 10 A
04400150A10 27A 15 A
04400172A10 31 A 17.2 A
05400220A10 39 A 22 A
05400270A10 48 A 27 A
05400300A10 53 A 30 A
06400350A10 62 A 35 A
06400420A10 74 A 42 A
06400470A10 83 A 47 A
07400660A10 116 A 66 A
07400770A10 135 A 77 A
07401000A10 175 A 100 A
08401340A10 235 A 134 A
08401570A10 275 A 157 A
09402000A10 350 A 200 A
09402240A10 385 A 220 A
10402700E 473 A 270 A
10403200E 543 A 310 A

For all above
Switching frequency 8 kHz (selectable 3 to 16 kHz @ 50% ED)
Braking transistor built in as standard

550 – 575 Vac, 50-60 Hz ± 10% Drive Ratings

PART NUMBER CURRENT (A)
Peak Current Nominal Current
05500030A10 5.5 A 3 A
05500040A10 7 A 4 A
05500069A10 12 A 6.9 A
06500100A10 17.5 A 10 A
06500150A10 26.5 A 15 A
06500190A10 33.5 A 19 A
06500230A10 40.5 A 23 A
06500290A10 51 A 29 A
06500350A10 54.5 A 31 A
07500440A10 77 A 44 A
07500550A10 96.5 A 55 A
08500630A10 110.5 A 63 A
08500860A10 150.5 A 86 A
09501040A10 182 A 104 A
09501310A10 229.5 A 131 A
10501520E10 266 A 152 A
10501900E10 332.5 A 190 A

For all above
Switching frequency 8 kHz (selectable 3 to 16 kHz @50% ED)
Braking transistor built in as standard

690 Vac, 50-60 Hz ± 10% Drive Ratings

PART NUMBER CURRENT (A)
Peak Current Nominal Current
07600190A10 33.5 A 19 A
07600240A10 42 A 24 A
07600290A10 51 A 29 A
07600380A10 66.5 A 38 A
07600440A10 77 A 44 A
07600540A10 84 A 48 A
08600630A10 110.5 A 63 A
08600860A10 150.5 A 86 A
09601040A10 182 A 104 A
09601310A10 229.5 A 131 A
10601500E10 262.5 A 150 A
10601780E10 311.5 A 178 A

For all above
Switching frequency 8 kHz (selectable 3 to 16 kHz @ 50 % ED)
Braking transistor built in as standard

Further information from your supplier is abailable on the following features:

  • UPS operation – all drives have a dedicated rescue mode allowing operations from 200 V UPS.
  • DC supply – all drives have the possibility of being supplied from a DC source from 24 V to the maximum voltage rating of the product.
  • 500 V, 525 V, 575 V and 690 V units are also available.
Your  Automations  Partner  Online